Different Types of chromatography Columns

This article contains detailed guide on the different Types of chromatography columns used in quality control laboratories, their properties, how they are used, maintenance and Frequently asked questions.

What is mean by Column used in laboratory for chromatographic Techniques?

a column is a device used for separating, identifying, and quantifying the components of a mixture. It is an important tool used in analytical chemistry to analyze and identify the properties of a sample.

Types of Chromatography Columns

There are two main types of chromatography used in quality control laboratories: Gas chromatography (GC) and Liquid chromatography (LC). Both GC and LC use different types of columns to separate and identify compounds.

Gas Chromatography Columns

Gas chromatography columns are mainly used to separate volatile compounds in a sample. These columns can be further divided into two types: packed columns and capillary columns.

Packed Columns

Packed columns are filled with a solid support material, such as silica gel or alumina. The sample is injected into the column and carried through the column by a carrier gas, such as helium or nitrogen. The compounds in the sample are separated based on their interaction with the support material and the carrier gas.

Capillary Columns

Capillary columns, also known as open-tubular columns, have a small diameter and are coated with a thin layer of liquid stationary phase. The sample is injected into the column and carried through by a carrier gas. Capillary columns provide high resolution and sensitivity due to their small diameter.

Liquid Chromatography Columns

Liquid chromatography columns are used to separate non-volatile compounds in a sample. There are four main types of liquid chromatography columns: reverse-phase, normal-phase, ion-exchange, and size-exclusion columns.

Reverse-Phase Columns

Reverse-phase columns are the most commonly used columns in quality control laboratories. They use a hydrophobic stationary phase and a polar mobile phase, such as water and methanol. The sample is injected onto the column and carried through by the mobile phase. The compounds in the sample are separated based on their hydrophobicity and interaction with the stationary phase.

Normal-Phase Columns

Normal-phase columns use a polar stationary phase and a non-polar mobile phase, such as hexane and ethyl acetate. Normal-phase columns are used to separate polar compounds.

Ion-Exchange Columns

Ion-exchange columns use a charged stationary phase to separate ions in a sample. The sample is injected onto the column and carried through by a mobile phase. The compounds in the sample are separated based on their charge and interaction with the stationary phase.

Size-Exclusion Columns

Size-exclusion columns, also known as gel-filtration columns, separate compounds based on their size. The column contains porous beads that allow small compounds to enter the beads while larger compounds are excluded. The compounds in the sample are separated based on their size and interaction with the beads.

Chromatography Column Properties

When choosing a column for a specific application, several column properties should be considered to achieve optimal separation and resolution.

Particle Size : Particle size refers to the size of the solid support material used in packed columns. A smaller particle size provides higher resolution and efficiency but also results in increased back pressure.

Pore Size : Pore size refers to the size of the pores in the solid support material used in packed columns. A larger pore size allows for better flow but also results in decreased resolution.

Surface Area : Surface area refers to the amount of stationary phase available for interaction with the sample in a column. A higher surface area provides higher resolution but also results in increased back pressure.

Length and Diameter :The length and diameter of a column also affect the resolution and efficiency of the separation. A longer column provides higher resolution but also results in increased retention time, while a wider column provides higher capacity but also results in decreased resolution.

Choosing the Right Column

Choosing the right column for a specific application can be challenging, as there are many factors to consider. The type of sample, the desired separation, and the available equipment should all be taken into account when selecting a column. It is also important to consider the column properties, such as particle size, pore size, surface area, and length and diameter.

Chromatography Column Maintenance and Troubleshooting

Proper column maintenance is essential for achieving optimal separation and resolution. Columns should be stored properly, cleaned regularly, and replaced when necessary. Troubleshooting column issues, such as poor resolution or high back pressure, can be challenging but is essential for achieving accurate results.

 

Frequently Asked Questions (FAQs)

  1. How do people know which column to choose for  specific application?
  • When selecting a column, it is important to consider the type of sample, the desired separation, and the available equipment, as well as the column properties such as particle size, pore size, surface area, and length and diameter.
  1. How often should  replace column?
  • Columns should be replaced when they begin to show signs of deterioration, such as a decrease in resolution or an increase in back pressure. Regular column maintenance can help prolong the life of a column.
  1. What should we do if we experience poor resolution or high back pressure?
  • Troubleshooting column issues can be challenging but is essential for achieving accurate results. First, check that the column is properly installed and that the mobile phase is properly prepared. If the issue persists, try cleaning the column or replacing it if necessary.
  1. What is the difference between packed columns and capillary columns?
  • Packed columns are filled with a solid support material, while capillary columns have a small diameter and are coated with a thin layer of liquid stationary phase. Packed columns are used for volatile compounds, while capillary columns are used for non-volatile compounds.
  1. What is the most commonly used type of liquid chromatography column?
  • Reverse-phase columns are the most commonly used type of liquid chromatography column in quality control laboratories. They use a hydrophobic stationary phase and a polar mobile phase and are used to separate non-volatile compounds.

 