Specification for Lami Tube.

This article describes the Specification for Lami Tube which is used to fill the external preparation formulations i.e. Ointment, Cream and Gel.

Specification for Lami Tube

I. Product Information:

Supplier / Manufacturer : As per approved vendor list
Sampling Procedure: Sampling to be performed as per current version of SOP
Sample Quantity : 10 Nos.

 

Testing procedure: Testing to be performed as per STP
Item code As per SOP
Storage Condition: Controlled Room temperature
Sampling and Handling Precautions

 (If Any):

Use personal protective equipments while handling the material.

 

II. Specification for Lami Tube:

Sr. No. Test Specification Reference
1. Description Printed Lami tube with cap. IH
2. Text matter Should be comply as per approved art work. IH
3. Diameter of Tube 16 mm + 1 mm IH
4. Overall length of tube with cap For Information IH
5. Length of tube from shoulder to bottom without cap 87 mm + 2 mm IH
6. Wall thickness of tube 0.20 mm + 0.02 mm IH
7. Nozzle diameter 7.80 mm + 0.20 mm IH
8. Nozzle length 6.5 mm + 0.5 mm IH
9. Collapsibility Test 2 mm + 0.1 mm IH
10. Color scheme Should be comply as per approved specimen. IH
11. Weight of tube without cap For Information IH
12. Weight of tube with cap 2.20 gm + 1 gm IH

 Remark: * Test to be carried out for Retesting of Packing Material.

III. Revision History: 

     Version No.

Reason for Revision

Change control No

   Effective Date

 

  

 