Standard test procedure for Aluminium Tube
This article consists of Standard test procedure for Aluminium Tube with cap used for filling of external preparations like Ointment, cream and Gel.
Standard test procedure for Aluminium Tube with cap
1.Description
Procedure: Printed Aluminium Tube with Cap.
Note down the results in test data sheet
2.Text Matter
Procedure: Should be comply as per approved artwork of the tube at least 5 nos.
Note down the results in test data sheet
3.Diameter of tube
Instrument: Vernier Caliper.
Procedure: To check the diameter of the tube at least 5 nos. using vernier caliper ,and take a average.
Note down the results in test data sheet of Standard test procedure for Aluminium Tube.
4.Overall length of the tube with cap
Instrument: Vernier Caliper.
Procedure: To check the overall length of the tube with cap at least 5 nos. using vernier caliper, and take a average.
Note down the results in test data sheet of Standard test procedure for Aluminium Tube
5. Length of the tube from shoulder to bottom without cap
Instrument: Vernier Caliper.
Procedure: To check the length of the tube from shoulder to bottom without cap using vernier caliper, and take a average.
Note down the results in test data sheet of Standard test procedure for Aluminium Tube
6.Wall thickness of the tube
Instrument: Digital Micrometer.
Procedure: To check the wall thickness of the tube using a micrometer, and take a average.
Note down the results in test data sheet
7. Nozzle Diameter
Instrument: Vernier Caliper.
Procedure: To check the nozzle diameter using vernier caliper, and take a average.
Note down the results in test data sheet of Standard test procedure for Aluminium Tube
8. Nozzle length
Instrument: Vernier Caliper.
Procedure: To check the nozzle length using vernier caliper, and take a average.
Note down the results in test data sheet of Standard test procedure for Aluminium Tube
9. Collapsibility test
Instrument: Vernier Caliper.
Procedure: To check the collapsibility of the tube at least 5 nos.& take a average.
Note down the results in test data sheet
10. Color of scheme
Procedure: As per approved shade card of the tube at least 5 nos.
Note down the results in test data sheet
11. Weight of the tube without cap (Printed)
Instrument: Analytical Balance.
Procedure: Weight at least 5 nos. of the tube by using a analytical balance.
Note down the results in test data sheet of Standard test procedure for Aluminium Tube
12. Weight of the tube with cap (Printed)
Instrument: Analytical Balance.
Procedure: Weight at least 5 nos. of the cap by using a analytical balance.
Note down the results in test data sheet of Standard test procedure for Aluminium Tube
13. Revision History:
Version No. |
Reason for Revision |
Change control No |
Effective Date |