Standard Test Procedure of Plastic container and Cap
This article consists of Packing material Standard Test Procedure of Plastic container and Cap.
Standard Test Procedure of Plastic container and Cap
1. Description:
Following visual checking to be carried out
Procedure: Examine the Plastic container (High Density Polyethylene (HDPE)/ Low Density Polyethylene (LDPE)/ Polyethylene Terephthalate (PET, PETE or polyester)) in day light for appearance. Round/square shape plastic container (High Density Polyethylene (HDPE)/ Low Density Polyethylene (LDPE)/ Polyethylene Terephthalate (PET, PETE or polyester)). Free from dust or any foreign particles.
There should not be any deformity in containers.
Note down the results in test data sheet of Standard Test Procedure of Plastic container and Cap
2. Weight of container:
Test to be performed on maximum five samples
Instrument: Analytical Balance
Procedure: Weigh the containers without cap on analytical balance.
Note down the results in test data sheet of Standard Test Procedure of Plastic container and Cap
3. Weight of cap:
(Test to be performed on maximum five samples)
Instrument: Analytical Balance
Procedure: Weigh the cap on analytical balance.
Note down the results in test data sheet
4. Neck outer diameter (OD) of container:
(Test to be performed on maximum five samples)
Instrument: Vernier caliper
Procedure: Measure the Neck OD of container by using Vernier caliper.
Note down the results in test data sheet of Standard Test Procedure of Plastic container and Cap
5. Neck inner diameter (ID) of container:
(Test to be performed on maximum five samples)
Instrument: Vernier calliper
Procedure: Measure the Neck ID of container by using Vernier caliper
Note down the results in test data sheet.
6. Body diameter of container:
(Test to be performed on maximum five samples)
Instrument: Vernier calliper
Procedure: Measure the Body diameter of container by using Vernier caliper.
Note down the results in test data sheet
7.Length of container:
(Test to be performed on maximum five samples)
Instrument: Vernier calliper
Procedure: Measure the Length of container by using Vernier caliper.
Note down the results in test data sheet of Standard Test Procedure of Plastic container and Cap
8. Width of container:
(Test to be performed on maximum five samples)
Instrument: Vernier calliper
Procedure: Measure the Width of container by using Vernier caliper.
Note down the results in test data sheet of Standard Test Procedure of Plastic container and Cap
9. Height of container:
(Test to be performed on maximum five samples)
Instrument: Vernier calliper
Procedure: Measure the Height of container without cap by using Vernier caliper.
Note down the results in test data sheet.
10. Outer diameter (OD) of cap:
(Test to be performed on maximum five samples)
Instrument: Vernier calliper
Procedure: Measure the OD of cap by using Vernier caliper.
Note down the results in test data sheet
11. Neck inner diameter (ID) of cap:
(Test to be performed on maximum five samples)
Instrument: Vernier calliper
Procedure: Measure the Neck ID of cap by using Vernier caliper.
Note down the results in test data sheet of Standard Test Procedure of Plastic container and Cap
12. Height of cap:
(Test to be performed on maximum five samples)
Instrument: Vernier calliper
Procedure: Measure the Height of cap by using Vernier caliper.
Note down the results in test data sheet
13. Thickness of wad:
(Test to be performed on maximum five samples)
Instrument: Vernier caliper
Procedure: Measure the Thickness of wad by using Vernier caliper.
Note down the results in test data sheet
14. Diameter of wad:
(Test to be performed on maximum five samples)
Instrument: Vernier caliper
Procedure: Measure the Diameter of wad by using Vernier caliper
Note down the results in test data sheet
Over flow capacity of container:
(Test to be performed on maximum five samples)
Equipment: Measuring cylinder
Procedure: Fill the container with water up to brimful
Then transfer the water in measuring cylinder and measure the volume in ml.
Note down the results in test data sheet
16. Performance criteria:
Procedure: Container and cap should fit with each other perfectly.
Note down the results in test data sheet of Standard Test Procedure of Plastic container and Cap.
17. Revision History:
Version No. | Reason for Revision | Change control No | Effective Date |