1. Description:

Following visual checking to be carried out

Procedure: Examine the Plastic container (High Density Polyethylene (HDPE)/ Low Density Polyethylene (LDPE)/ Polyethylene Terephthalate (PET, PETE or polyester)) in day light for appearance. Round/square shape plastic container (High Density Polyethylene (HDPE)/ Low Density Polyethylene (LDPE)/ Polyethylene Terephthalate (PET, PETE or polyester)). Free from dust or any foreign particles.

There should not be any deformity in containers.

Note down the results in test data sheet of Standard Test Procedure of Plastic container and Cap

2. Weight of container:

Test to be performed on maximum five samples

Instrument: Analytical Balance

Procedure: Weigh the containers without cap on analytical balance.

Note down the results in test data sheet of Standard Test Procedure of Plastic container and Cap

3. Weight of cap:

(Test to be performed on maximum five samples)

Instrument: Analytical Balance

Procedure: Weigh the cap on analytical balance.

Note down the results in test data sheet

4. Neck outer diameter (OD) of container:

(Test to be performed on maximum five samples)

Instrument: Vernier caliper

Procedure: Measure the Neck OD of container by using Vernier caliper.

Note down the results in test data sheet of Standard Test Procedure of Plastic container and Cap

5. Neck inner diameter (ID) of container:

(Test to be performed on maximum five samples)

Instrument: Vernier calliper

Procedure: Measure the Neck ID of container by using Vernier caliper

Note down the results in test data sheet.

6. Body diameter of container:

(Test to be performed on maximum five samples)

Instrument: Vernier calliper

Procedure: Measure the Body diameter of container by using Vernier caliper.

Note down the results in test data sheet

7.Length of container:

(Test to be performed on maximum five samples)

Instrument: Vernier calliper

Procedure: Measure the Length of container by using Vernier caliper.

Note down the results in test data sheet of Standard Test Procedure of Plastic container and Cap

8. Width of container:

(Test to be performed on maximum five samples)

Instrument: Vernier calliper

Procedure: Measure the Width of container by using Vernier caliper.

Note down the results in test data sheet of Standard Test Procedure of Plastic container and Cap

9. Height of container:

(Test to be performed on maximum five samples)

Instrument: Vernier calliper

Procedure: Measure the Height of container without cap by using Vernier caliper.

Note down the results in test data sheet.

10. Outer diameter (OD) of cap:

(Test to be performed on maximum five samples)

Instrument: Vernier calliper

Procedure: Measure the OD of cap by using Vernier caliper.

Note down the results in test data sheet

11. Neck inner diameter (ID) of cap:

(Test to be performed on maximum five samples)

Instrument: Vernier calliper

Procedure: Measure the Neck ID of cap by using Vernier caliper.

Note down the results in test data sheet of Standard Test Procedure of Plastic container and Cap

12. Height of cap:

(Test to be performed on maximum five samples)

Instrument: Vernier calliper

Procedure: Measure the Height of cap by using Vernier caliper.

Note down the results in test data sheet

13. Thickness of wad:

(Test to be performed on maximum five samples)

Instrument: Vernier caliper

Procedure: Measure the Thickness of wad by using Vernier caliper.

Note down the results in test data sheet

14. Diameter of wad:

(Test to be performed on maximum five samples)

Instrument: Vernier caliper

Procedure: Measure the Diameter of wad by using Vernier caliper

Note down the results in test data sheet

Over flow capacity of container:

(Test to be performed on maximum five samples)

Equipment: Measuring cylinder

Procedure: Fill the container with water up to brimful

Then transfer the water in measuring cylinder and measure the volume in ml.

Note down the results in test data sheet

16. Performance criteria:

Procedure: Container and cap should fit with each other perfectly.

Note down the results in test data sheet of Standard Test Procedure of Plastic container and Cap.

 